Instrument designed to characterize materials according to their Surface Resistivity
and Resistance.
•
Readings in decades; Range from-10E3 to 10E12 ohms per square.
•
Measuring voltage: 10 V- for conductive and 100V- for static dissipative.
•
Operates on 9V battery with indication for low battery.
•
Provision for measuring both point-to-point and surface to ground resistances using
electrodes compliant to ESD Association Standards.
•
Can be used for measuring surface to ground resistance using a single electrode.
•
Calibration certificate and one year warranty provided.
•
Compliant to EN Norms- CE mark certified by UL India.
Wrist strap and footwear tester
•
Designed to validate wrist straps for use at ESD stations through pass/ no pass
light and audio indication.
•
Easy to operate instrument, with pass indicator for resistance between 0.75 and
10 megohms.
•
Operates on 9 V battery, with low battery indicator.
•
Calibration certificate and one year warranty provided.
•
This instrument can also be used to measure ESD.
•
Footwear with the use of an optional footplate arrangement.
Combo Tester
Now you can easily and reliably restrict the entry of personnel without valid personnel
grounding into EPAs (ESD Protected Areas) by using a Combo Tester. The system consists
of a tester (combo tester) to validate the wrist straps and footwear, which is connected
to the Access Control (magnetic lock) of the door. When personnel enter the EPA,
they need to test their wrist strap/ESD footwear. If the resistance of the wrist
strap / ESD footwear is within acceptable range as per the ANSI ESD S20.20 standard,
the door is opened by release of the Magnetic Lock on the door. The instrument shows
the result on a PASS or FAIL Basis.
Workstation Monitor Watch
Continuous workstation & wrist strap monitor has independent circuitry, designed
to continuously monitor the connections to earth of the Wrist Strap and Work Surface.
Wrist Strap
This section continuously monitors the wrist strap to detect loss of continuity
between operator and monitor. Conditions such as broken coil cords and improper
contact with the skin are detected instantly to alert the operator before serious
and expensive ESD damage can occur. As there is no resistive return path from the
wrist strap, it uses the 'Capacitive AC pulse principle' to check if the operator
is adequately grounded. The Wrist Strap section is automatically activated when
it is plugged in. Continuous monitoring reduces the need for periodic checks and
audits and greatly increases the convenience.
ESD Work Surface
The work surface is monitored by a DC Resistive principle and a warning is given
in case the Surface-to-Ground resistance exceeds the safe threshold value of 10
meg ohms.
Static Sensor
A sensitive instrument designed to give a response to any static generating surface
when the surface is scanned in front of the sensor.
•
Senses static voltage beyond 50 V
•
Response is both Audio and Visual
•
Operates on 9 V
•
Can be used to check packaging material for both static generation and static shielding
The relentless saga of growth through research and development continued during
2007 at Cir-Q-Tech Tako Technologies...
A JV with Tako Astatic Technologies Sdn.Bhd, a market leader in ESD Control products
in Malaysia, has empowered Cir-Q-Tech to offer...
Cir-Q-Tech has set a benchmark for others to follow in field of ESD control by acquiring
and retaining the ISO 9001:2000 certificate since 2004.
Copyright ® 2008 cir-q-tech tako technologies Pvt. Ltd